Sign In | Join Free | My himfr.com
Home > Mainstream Etco2 Sensor >

OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor

Hung-Kee (China) Electronic Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor from wholesalers
     
    Buy cheap OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor from wholesalers
    • Buy cheap OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor from wholesalers
    • Buy cheap OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor from wholesalers
    • Buy cheap OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor from wholesalers

    OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor

    Ask Lasest Price
    Brand Name : Hung-Kee
    Model Number : MCD-09
    Certification : IEC
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 2000 pcs per month
    Delivery Time : 5 to 30 days
    MOQ : 1 pc
    • Product Details
    • Company Profile

    OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor

    Mainstream EtCO2 Sensor Portable patient monitor Veterinary multiparameter monitor mainstream capnography sensor


    End-tidal CO2 sensor mainstream module ICU/OR monitoring EtCO2 module 2 year warranty MCD-09


    Mainstream EtCO2 Sensor Quick Details:


    The model MCD-09 Mainstream EtCO2 Sensor is a stable and reliable end-tidal CO2 module with high integrity, developed by Hung-kee, adopting the non-dispersive infrared technology with two wavebands, the latest microprocessor and digital signal processing technique, and proven concentration algorithm. The module can accurately measure the concentration of the end-tidal CO2, the concentration of the inhaled CO2, respiratory rate, etc. with the CO2 curve diagram in a fast and exact manner. This mainstream EtCO2 sensor is perfectly applicable to person at different age group, such as baby, child and adult. The sampling flow rate is setup on the upper computer, and the minimum rate can be lowered to 50ml/min.


    1. Uses non-dispersive infrared technology to measure EtCO2 from respiratory gases

    2. Supports adult, pediatric and neonatal patients

    3. Real time CO2 monitoring and data upload

    4. Dual wavelength, non-dispersive infrared(NDIR)


    Hung-Kee EtCO2 brochure 2022.01.pdf


    Mainstream EtCO2 Sensor Technical details:


    Transducer TypeMainstream CO2 Sensor
    Principle of OperationNon-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts.
    Energy Emitting DeviceHigh efficiency IR source
    Energy Detecting DeviceFrequency stable thermopile
    CO2 Measurement Range0% to 20% (0 to 150mmHg)
    CO2 Resolution

    0.1 mm Hg 0 to 49 mm Hg

    0.2 mm Hg 50 to 150 mm Hg

    CO2 Accuracy±2 mm Hg @ < 5.0% CO2 (at BTPS)
    < 10% of reading @ > 5.0%CO2(at BTPS)
    Dimensions50mm*22mm*36mm
    Weight< 40g
    Respiration Rate Range3 to 150 Breaths Per Minute (BPM)
    Respiratory Rate Accuracy1% of reading ±1 breath
    Calibration

    No routine user calibration required. An airway adapter zero is required

    when changing to a different style of airway adapter.

    Data InterfaceHighly configurable serial digital interface (TTL/RS232 Level)
    Data OutputCO2 gas concentration (mmHg), End-tidal CO2, Inspired CO2, Respiratory Rate.
    Input Voltage5.0 VDC ±5%
    Power Consumption1000mW
    Warmup Time10 seconds
    Response Time10mS
    Operating Temperature5℃ to 55℃
    Shipping/Storage
    Temperature Range
    -40℃ to 70℃

    ( for more detailed technical data please refer to above PDF brochure)


    Mainstream EtCO2 Sensor Description:


    The Hung-kee EtCO2 capnograph respiratory CO2 Module provides mainstream and sidestream measuring capabilities, enables continuous respiratory monitoring to help reduce risks of opioid-induced respiratory depression of adult, pediatric and neonatal patients.


    1.Long-term stability, non-dispersive infrared technology with two wavebands
    2.Long service life, infrared black body light source with MEMS
    3.Accurate Results, with built-in temperature, atmospheric pressure, compensation algorithm for the balance gas
    4.Calibration-free, patented calibration algorithm without the need for calibration


    Mainstream EtCO2 Sensor Accessory:


    Adult way adapter


    FAQ for Mainstream EtCO2 Sensor:


    1. Q: When do you delivery?
    A: Usually in 7-30 days depends on the order qty and available of some specific parts.

    2.Q: Do you work on OEM and SKD project?

    A: Yes, we have more than 14 years experience on OEM and SKD service, full assembling procedure will be provided, and detailed guidance of local assembling work will be offered.

    3.Q: Where is your company located?

    A: Our company is located in Shenzhen city, very near from Hongkong(about one and half hours)


    4. Q: Can I order a sample?
    A: Sure, delivery sample by global express in charge.


    5.Q: Are you trading company or manufacturer?

    A: We are factory which has over 14 years' manufacturing experience.


    6.Q: What's the MOQ?

    A: 1 unit.


    7.Q: How to deal with the faulty?

    A: First, our products are produced in strict quality control system, but if any faulty, we'll send new spare parts for free within 2 warranty years. Secondly, our after-sales department will periodically follow up customers.


    8.Q: How can get the shipping cost?

    A: You tell us your destination port or delivery address, we check the Sea Freight or Air Freight or express for you based on your requirement.


    9.Q:How Can We Guarantee Quality?

    A: Each Production Step Has Two Times Inspection, Engineers Simulating Actual Operation Of Each Machine Before Shipping.


    10.Q: How long is your delivery time?

    A: 5 - 30 days after order confirmed. Based on the item and quantity.


    11.Q: What is your terms of payment?

    A: T/T, Western Union or PayPal; Trade terms: CIF


    12.Q: Where's your general loading port?

    A: Shenzhen or Hongkong port, as your demand.


    Quality OEM Plastic Mainstream Etco2 Sensor For Veterinary Multiparameter Monitor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hung-Kee (China) Electronic Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)